In Supplementary Table 1 and 2, we show additional results on comparing TEXTGRAD optimized plan with clinicians optimized plans.

Supplementary Table 1: PTV dose metrics. Several dose metrics of the PTV target are displayed for all the clinical and TextGrad optimized plans, including the mean and minimum doses, as well as the D95D_{95} . For all the metrics, we include the average deviations from the clinical goal across 5 plans and the standard deviation in brackets. Values in bold represent the best for each PTV target.

TargetMethodMean dose [Gy]Min dose [Gy]Max dose [Gy]D95 [Gy]
PTVClinical Goal70.20≈ 70.20≈ 70.2070.20
Radiation Oncologist+1.97 (0.36)-8.88 (2.31)+4.66 (0.82)-0.10 (0.15)
TEXTGRAD+0.51 (0.09)-8.48 (2.38)+3.63 (0.87)+0.00 (0.00)

Supplementary Table 2: Organs at Risk (OARs) dose metrics. We show mean dose capturing OAR sparing. Lower values demonstrate better OAR sparing which is desirable, as this number indicates organs at risk, which should not get more than dosage than what is listed in the clinical guidelines. For all the metrics, we include the average mean dose across 5 plans and the standard deviation in brackets.

OrganMethodMean dose [Gy] ↓D5↓D50↓
RectumRadiation Oncologist23.88 (6.45)64.26 (10.00)20.04 (5.50)
TEXTGRAD17.18 (4.2)58.82 (18.81)9.54 (0.70)
BladderRadiation Oncologist22.39 (5.55)67.81 (6.44)14.78 (8.42)
TEXTGRAD20.92 (0.79)65.96 (6.96)14.11 (3.17)